Preclinical formulation
Equipment
- Restricted and controlled access to the laboratory
- Availability of main reference drugs
- Laminar
air flow hood equipped with 3 HEPA H14 filters and an anti-vibration
surface (marble top) dedicated to the precise weighing of powders under
protected atmosphere: protection of products, handlers and environment
- Semi-micro balance with an accuracy of 0.01mg under 41g and 0.1mg under 120g
- Dedicated refrigerator, freezer and safety cupboards of products
|
Experiments performed by the laboratory
- Pre-clinical formulation of test substances before administration to rodents:
suspension/solution of known and unknown products
- Preparation of test substances supplied by sponsor following SOP
- Stability studies of compounds in vehicle for administration
- Storage and management of tested compounds
Aim of these experiments in drug development
- To
enhance drug bioavailability and absorption by the development of new
solutions/suspensions compatible with administration to rodents
involved in tolerance and antitumor activity studies
- To compare the activity of new formulations with actual galenic forms
- To guarantee the reproducibility of drug preparation for administration to rodents
|
|
|